3. Technical Data
3.1 Explosion Protection
Type : 17-A129-0G.0/H...... and 17-A129-0K.0/H...….
Ex protection type
:
Class
Ι Div 1 Groups C and D, T4 Ex ia
Certification : File No. E226123
3.2 General Data
Dimensions (height x width x depth)
Type 17-A129-0G.0/H....... Version "Gun" : 231 mm x 91 mm x 193 mm 9.1 inch x 3.6 inch x 7.6 inch
Type 17-A129-0K.0/H....... Version "Brick" : 231 mm x 91 mm x 56 mm 9.1 inch x 3.6 inch x 2.2 inch
Ambient temperature : -20 °C to +40 °C -4 °F to 104 °F
Ambient temperature when charging : 0 °C to +40 °C 32 °F to 104 °F
Storage temperature : -40 °C to +70 °C -40 °F to 158 °F
outside the hazardous area
Air humidity : 5 % to 95 % (not condensing)
Protection class : IP 64 (EN 60529)
Weight including battery
Type 17-A129-0G.0/H....... Version "Gun" : approx. 720 g approx. 23 oz
Type 17-A129-0K.0/H....... Version "Brick" : approx. 680 g approx. 22 oz
Display : 3.8 inch ¼ VGA colour display
65536 colours
240 x 320 pixels
Touch panel : Polycarbonate, analog resistive touch
Processor : Intel® XScale Bulverde PXA270 processor with 624 MHz
Operating system
: Windows Mobile 2005 (English)
Memory
:
ROM 128 MB RAM 64 MB
optional extension with SD card : 512 MB Order number 17-28BE-F006/0001
1 GB Order number 17-28BE-F006/0002
2 GB Order number 17-28BE-F006/0003
Note:
The devices are modified to suit the selected memory
versions. The end user can replace the SD card later himself,
but must follow the instructions in chapter 6.1.4